Description
Product Description
Ethox 4005 - Infu-Surg Pressure Infusion Bag, 500cc, 5/BOX
Ethox 4005 Infu-Surg Pressure Infusion Bag
The latex free Infu-Surg Pressure Infusion Bag is a safe, highquality, reliable device for intravenous and intra-arterial infusion treatment, including A-line pressure monitoring. Designed for single patient use, the Infu-Surg may help prevent and control cross-contamination and hospital acquired infections. The InfuSurg is a cost-effective, trusted product that medical professionals have relied on for decades. The dedicated fluid bag hook enables efficient loading and unloading of the system without having to remove the infusion bag from the IV pole.
Ethox 4005 Infu-Surg Pressure Infusion Bag Features & Benefits
- Pressure relief valve prevents over inflation (330 mmHg pressure relief)
- Large, oval shaped bulb allows for quick and easy inflation of bladder
- Single-handed inflation and deflation design makes it easy to use and requires minimal training
- Suitable for use with external inflation sources
- Color-coded gauge makes for accurate pressure monitoring (0-300 mmHg)
- Three-way stopcock ensures precise control of pressure
- Incredibly reliable - 100% tested
- Loads quickly and easily
- Latex free, single patient, non-sterile
Instructions for Use of Ethox 4005 Infu-Surg Pressure Infusion Bag
- Remove pressure infusion bag from package, unfold pressure bag and hang pressure bag on to IV pole by the loop located at the top of the pressure bag (Figure 1).
- Insert intravenous bag between mesh panel and pressure bag on 4050H and 4010H only.
- If using clarity bag 4005 or 4100, place intravenous bag between clear panel and pressure bag.
- Hang loop of intravenous bag on to welded solution bag hook located just above panel on pressure bag (Figure 1).
- FOR 4030 ONLY: Slide hanger loop through top of 3000 ml intravenous bag and rehang on IV pole.
- Inflate pressure infusion bag by rotating the off portion of the valve/stopcock to the right. Pump inflation bulb until gauge reaches the proper pressure (300 mmHg) indicated in the green portion on the manometer (Figure 2).
- Once proper pressure is reached on gauge, rotate off portion of the valve/stopcock straight up towards the pressure bag to maintain pressure in bag. NOTE: precise positioning of valve/stopcock is important or bag could lose pressure.
- To deflate bag turn the off portion on the valve/stopcock straight down towards inflation bulb to release pressure in bag.
- Proper valve positioning is illustrated on all pressure bags.