Teleflex AI-07130 - Arrow Berman Angiographic Catheter for Balloon Occlusion Femoral Angiography (BOFA) Ipsilateral Approach, EACH
Teleflex AI-07130 Arrow Berman Angiographic Catheter
The Arrow Berman Angiographic Catheters from Teleflex may help reduce patient complications during pulmonary angiography procedures and Balloon Occlusion Femoral Angiography (BOFA). Berman catheters provide a high flow of dye injection through side holes that optimize dye distribution and minimize the risk of arrhythmias, and myocardial staining by directing dye away from the myocardial wall.
- Arrow-Berman Catheters allow injection of contrast media proximal or distal to the balloon for different techniques
French Size | Introducer Size Recomd |
Recomd Useful Length |
Balloon Inflation Capacity |
5 Fr | 5 or 6 Fr | 50 cm | 0.75 cc |
Inflated Balloon Diameter |
Max. Wire Recomd |
Max. Flow Rate |
Max. Injection Pressure |
8.0 mm | 0.032 in | 15 cc/sec | 540 p.s.i.g |
Features and Benefits of Teleflex AI-07130 Arrow Berman Angiographic Catheter
Only Teleflex Carries the Berman Catheter
- Available in two configurations
- Standard Berman Catheter
- Reverse Berman Catheter
- BOFA for Ipsilateral Approach
Catheter Design Provides Higher Flow and Fewer Complications
- Junction hub and extension line design offers higher flow rates and injection pressures (Details provided for each product in ordering information table)
- Injectate outflow design optimizes dye distribution and minimizes risk of arrhythmias and myocardial staining by directing dye away from the myocardial wall
Designed In a Wide Range of French Sizes and Lengths to Meet a Variety of Clinical Needs
- Available in 4, 5, 6, 7 and 8 French catheter sizes
- Selected French sizes available in lengths from 50 - 110 cm
- Clinical uses include:
- Pulmonary angiography
- Balloon Occlusion Femoral Angiography (BOFA)
- Color-coded injectate port
- Standard Berman is Pink
- Reverse Berman is Blue
Smooth Flexible Catheter Body Facilitates Insertion and Positioning
- Arrow PVC Catheters offer greater control and manipulation
- Flotation control allows blood flow to carry the inflated balloon naturally through the ventricle and into the pulmonary artery
- Catheter tip position may be determined by continuous pressure monitoring
- Unique tapered-tip construction ensures that the diameter of the deflated balloon does not exceed the diameter of the catheter body, facilitating percutaneous insertion by sheath matched to catheter size and reduced blood loss
- Each catheter has clear, easy to identify increment markings every 10 cm to confirm insertion depth
TeleflexAI-07130 Arrow Berman Angiographic Catheter Device Characteristics
What MRI safety information does the labeling contain? | Labeling does not contain MRI Safety Information |
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437): | Yes |
Device labeled as "Not made with natural rubber latex": | No |
For Single-Use: | Yes |
Prescription Use (Rx): | Yes |
Over the Counter (OTC): | No |
Kit: | No |
Combination Product: | No |
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P): | No |